AL.502 STO B signal lost or error – Delta servo troubleshooting

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear
Way

AL.502

STO B lost

STO_B lost (signal loss or signal error)   NO Cycle power on

Causes Checking Method Actions
Loss of STO_B signal or STO_A and STO_B signals are not synchronized for more than 1 second. Make sure the wiring of STO_B is correct.

Cycle power on the servo drive.

(The above information is referenced from Delta Electronics IMSBU)

 ↓ The following content is contributed by users ↓

Other reasons Checking Method Actions
     
     

Sharing is a virtue. Please add the inadequacies of this article to benefit the public —

Leave a Reply