Chapter 8  Parameters  ASDA-A2 
8-290     Revision February, 2017 
Setting Value: 0x0E 
DO Name  Function Description of Digital Output (DO)  Control Mode 
IDXD  Indexing coordinates is valid.  PR 
 
Setting Value: 0x10 
DO Name  Function Description of Digital Output (DO) 
Trigger 
Method 
Control 
Mode 
OLW  When reaching the overload setting, this DO is ON. 
t
OL
= Overload allowable time of the servo x Setting value of P1-56, 
when the overload accumulative time exceeds t
OL, 
it will 
output pre-overload warning (OLW). However, if the overload 
accumulative time exceeds the overload allowable time of the 
servo, it will output pre-overload error (ALRM). 
For example: 
The setting value of pre-overload warning is 60% (P1-56=60). 
When the output average load of the servo drive is 200%, if the 
output time exceeds 8 seconds, the servo drive will show the 
overload alarm (AL.006). 
t
OL
= The output average load of the servo exceeds 200% for 8 
seconds x parameter setting value = 8sec x 60% = 4.8sec 
Result: When the output average load of the servo drive exceeds 
200% for 4.8 seconds, this DO is ON. If it exceeds for 8 seconds, 
then, DO.ALRM is ON. 
Level 
triggered 
ALL 
 
Setting Value: 0x11 
DO Name  Function Description of Digital Output (DO) 
Trigger 
Method 
Control 
Mode 
WARN  Warning output (Forward / reverse limit, emergency stop, 
communication error, under voltage) 
Level 
triggered 
ALL 
 
Setting Value: 0x12 
DO Name  Function Description of Digital Output (DO) 
Trigger 
Method 
Control 
Mode 
OVF  Position Command /Feedback Overflows  Level 
triggered 
PR 
 
Setting Value: 0x13 
DO Name  Function Description of Digital Output (DO) 
Trigger 
Method 
Control 
Mode 
SNL 
(SCWL) 
Software limit (Reverse limit)  Level 
triggered 
ALL