AL.011 Encoder Error – Delta servo troubleshooting

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear
Way

AL.011

Encoder Error

The encoder produces abnormal pulse   No re-power on

Causes Checking Method Actions
Wrong wiring of the encoder Check if the wiring follows the suggested wiring of the user manual. Correct wiring
The encoder is loose Check the drive connector of CN2 and encoder Install the encoder again
Bad connection of the encoder Check if the connection between CN2 of the drive and the encoder of the servo motor is loose Reconnect the wiring
The encoder is damaged Check if the motor is damaged Change the motor
     

(The above information is referenced from Delta Electronics IMSBU)

See ALL Alarms <=        ↓ The following content is contributed by users ↓

Other reasons Checking Method Actions
     
     

Sharing is a virtue. Please add the inadequacies of this article to benefit the public —

Leave a Reply