<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.289 Position counter overflows |
Position counter overflows |
⊗ | Yes |
DI.ARST |
Alarm handling
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.289 Position counter overflows |
Position counter overflows |
⊗ | Yes |
DI.ARST |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.126 Specified object does not support PDO mapping |
Specified object does not support PDO mapping |
⊗ | Yes |
NMT:Reset node 或0x6040.Fault Reset |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.125 PDO object is read-only and write-protected |
PDO object is read-only and write-protected |
⊗ | Yes |
NMT:Reset node 或0x6040.Fault Reset |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.127 PDO Write prohibited while Servo Enabled |
PDO object is write-protected when servo drive is on (enabled) |
⊗ | Yes |
NMT:Reset node 或0x6040.Fault Reset |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.099 DSP Firmware Upgrade |
EEPROM has not been reset after DSP firmware is upgraded. | ⊗ | No | Firstly set P2-08 to 30 ,then set it to 28. And the alarm will be cleared after power cycling. |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.095 no external regenerative resistor error |
As for the 220V 5.5 kW model or above, if the value of P1-53 is not 0 and the external regenerative resistor or the brake is not connected, the alarm occurs. | ⊗ | Yes | DI.ARST ↑ |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.085 Regeneration setting error |
Regeneration control error | ⊗ | No | DI.ARST ↑ |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.083 Servo drive excessive current |
When the output current from servo drive exceeds the setting level, AL083 will be triggered to protect IGBT. This could avoid IGBT to be burned out because of the excessive current. | ⊗ | No | DI.ARST ↑ |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.070 Encoder does not complete the command issued by |
Command is not completed when the barcode is written to the encoder. | ⊗ | No | after power cycling |
<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.06A The absolute |
The absolute origin coordinate has not been created. The possible causes might be:
|
⊗ | Yes | The alarm can be cleared after creating the absolute origin coordinate. |