<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.007 Overspeed |
The control speed of the motor exceeds the normal speed | ⊗ | NO | DI.ARST |
Causes | Checking Method | Actions |
---|---|---|
Unreasonable command | Use the scope to check if the signal of analog voltage is abnormal | Less steep command used or filter applying to smooth command |
Inappropriate parameter setting | Check if the setting of parameter P2-34 is too small (the condition of over-speed warning) | Correctly set parameter P2-34 (the condition of over-speed warning) |
(The above information is referenced from Delta Electronics IMSBU)
↓ The following content is contributed by users ↓
Other reasons | Checking Method | Actions |
---|---|---|
UVW bad contact (Archer) |
|
Reinstall or Wiring |
— Sharing is a virtue. Please add the inadequacies of this article to benefit the public —