AL.213 Para Value of PR Writing cmd is out of range – Delta servo troubleshooting

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear Way

AL.213

PR Writing Para value

out of range

Para Value of PR Writing cmd is out of range

  Yes

DI.ARST

Trigger condition

and cause

  • Condition: when you use Type [8] PR command to write the parameter, the parameter value is incorrect.
  • Cause: an error occurs when you write the parameter with Type [8] PR command.

Checking method

and corrective action

Make sure the parameter value is within the correct range.
How to clear the alarm? DI.ARST

(The above information is referenced from Delta Electronics IMSBU)