<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.501 STO A lost |
STO_A lost (signal loss or signal error) | ⊗ | NO | Cycle power on |
Causes | Checking Method | Actions |
---|---|---|
Loss of STO_A signal or STO_A and STO_B signals are not synchronized for more than 1 second. | Make sure the wiring of STO_A is correct. |
Cycle power on the servo drive. |
(The above information is referenced from Delta Electronics IMSBU)
↓ The following content is contributed by users ↓
Other reasons | Checking Method | Actions |
---|---|---|
— Sharing is a virtue. Please add the inadequacies of this article to benefit the public —