<= See All alarms of Delta servo
Name | Description | ALM | WRN | SRV ON | Clear Way |
---|---|---|---|---|---|
AL.122 PDO Object’s sub-index not exist |
Object’s sub-index does not exist when PDO is accessed |
⊗ | Yes |
NMT:Reset node 或0x6040.Fault Reset |
Trigger condition and cause |
When the servo drive receives the PDO from the controller, the specified object’s sub-index number is incorrect, so the servo drive cannot identify it. |
Checking method and corrective action |
|
How to clear the alarm? | NMT: reset node, 0x6040 fault reset, or DI.ARST. |
(The above information is referenced from Delta Electronics IMSBU)
--- ↓ The following content is contributed by users ↓---
cause |
|
actions |
|
How to clear? |
— Sharing is a virtue. Please add the inadequacies of this article to benefit the public —