AL.122

PDO Object’s sub-index

not exist

Object’s sub-index does not exist when PDO is accessed

  Yes

NMT:Reset node 或0x6040.Fault Reset

Trigger condition

and cause

When the servo drive receives the PDO from the controller, the specified object’s sub-index number is incorrect, so the servo drive cannot identify it.

Checking method

and corrective action

  1. Check if the object’s sub-index number for PDO mapping of the controller is correct.
  2. If the sub-index number is correct, it means this specified object is not supported by the servo drive. Check if it is necessary to use this object or if you can substitute it with a different object.
How to clear the alarm? NMT: reset node, 0x6040 fault reset, or DI.ARST.

(The above information is referenced from Delta Electronics IMSBU)

---  ↓ The following content is contributed by users ↓---

cause

 

actions

 
How to clear?  