<= See All alarms of Delta servo
Name |
Description |
ALM |
WRN |
SRV ON |
Clear
Way |
AL.028
|
Charging circuit of the servo drive is not removed and the battery voltage is higher than the specification (>3.8 V) or the encoder signal is error |
⊗ |
|
NO |
Re-power on |
Causes |
Checking Method |
Actions |
Battery voltage is too high |
- Check if the charging circuit exists in the servo drive.
- Check if the battery is correctly installed
|
- According to the procedure of Over voltage to check. When corrective actions are done, AL.028 will be cleared automatically.
|
The internal encoder is error. |
- Check if it is the absolute type encoder.
- Check if the servo is properly grounded.
- Check if the encoder cable separates from the power supply or the high-current circuit to avoid the interference.
- Check if the shielding cables are used in the wiring of the encoder
|
- If the situation is not improving,please send the drive back to the distributors or contact with Delta.
- Please connect the UVW connector (color green) to the heat sink of the servo drive.
- Please check if the encoder cable separates from the power supply or the high-current circuit.
- Please use shielding mesh. If the situation is not improving, please send the drive back to the distributors or contact with Delta.
|
(The above information is referenced from Delta Electronics IMSBU)
See ALL Alarms <= ↓ The following content is contributed by users ↓
Other reasons |
Checking Method |
Actions |
|
|
|
|
|
|
— Sharing is a virtue. Please add the inadequacies of this article to benefit the public —
相關文章/Related Posts: