AL.067 Encoder temperature warning – Delta servo troubleshooting

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear
Way

AL.067

Encoder temperature warning

Encoder temperature exceeds the warning level.

(But it is still within the protective range.)

  Yes DI:ARST

Causes Checking Method Actions
Encoder temperature exceeds the warning level. (But it is still within
the protective range 85°C to 100°C, 185°F to 212°F.)
Check the setting: Set the value of P0-02 to 120 to display the temperature.
  1. Improve heat dissipation or reduce the loading of operation. The temperature should be lower than 100°C (212°F).
  2. If the encoder’s temperature is higher than the motor’s (more than 30°C (86°F)). Please send the motor back to the distributors.

(The above information is referenced from Delta Electronics IMSBU)

See ALL Alarms <=        ↓ The following content is contributed by users ↓

Other reasons Checking Method Actions
     

Sharing is a virtue. Please add the inadequacies of this article to benefit the public —