Delta Servo

Delta servo drive

AL.124 Data out of range when PDO is accessed – Delta servo troubleshooting

Archer Delta servo Alarms 2021-05-032021-05-03 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear Way

AL.124

Data out of range when PDO is accessed

Data out of range when PDO is accessed

⊗   Yes

NMT:Reset node 或0x6040.Fault Reset

Read more

AL.123 Data length error occurs when PDO is accessed – Delta servo troubleshooting

Archer Delta servo Alarms 2021-05-03 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear Way

AL.123

Data length error occurs when PDO is accessed

Data length error occurs when PDO is accessed

⊗   Yes

NMT:Reset node 或0x6040.Fault Reset

Read more

AL.122 PDO Object’s sub-index does not exist – Delta servo troubleshooting

Archer Delta servo Alarms 2021-05-03 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear Way

AL.122

PDO Object’s sub-index

not exist

Object’s sub-index does not exist when PDO is accessed

⊗   Yes

NMT:Reset node 或0x6040.Fault Reset

Read more

AL.121 PDO Object’s index does not exist – Delta servo troubleshooting

Archer Delta servo Alarms 2021-05-032021-05-03 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear Way

AL.121

PDO Object’s index

not exist

Object’s index does not exist when PDO is accessed

⊗   Yes

NMT:Reset node 或0x6040.Fault Reset

Read more

AL.127 PDO Write prohibited while Servo Enabled – Delta servo troubleshooting

Archer Delta servo Alarms 2021-04-302021-05-03Alarm handling 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear Way

AL.127

PDO Write prohibited while Servo Enabled

PDO object is write-protected when servo drive is on (enabled)

⊗   Yes

NMT:Reset node 或0x6040.Fault Reset

Read more

AL.099 DSP Firmware Upgrade – Delta servo troubleshooting

Archer Delta servo Alarms 2021-04-292021-04-29Alarm handling, Delta Servo 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear
Way

AL.099

DSP Firmware Upgrade

EEPROM has not been reset after DSP firmware is upgraded.  ⊗   No Firstly set P2-08 to 30 ,then set it to 28. And the alarm will be cleared after power cycling.

Read more

AL.095 No external regenerative resistor error – Delta servo troubleshooting

Archer Delta servo Alarms 2021-04-29Alarm handling, Delta Servo 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear
Way

AL.095

no external regenerative resistor error

As for the 220V 5.5 kW model or above, if the value of P1-53 is not 0 and the external regenerative resistor or the brake is not connected, the alarm occurs.   ⊗ Yes DI.ARST ↑

Read more

AL.085 Regeneration setting error – Delta servo troubleshooting

Archer Delta servo Alarms 2021-04-29Alarm handling, Delta Servo 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear
Way

AL.085

Regeneration setting error

Regeneration control error ⊗   No DI.ARST ↑

Read more

AL.083 Servo drive excessive current – Delta servo troubleshooting

Archer Delta servo Alarms 2021-04-29Alarm handling, Delta Servo 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear
Way

AL.083

Servo drive excessive current

When the output current from servo drive exceeds the setting level, AL083 will be triggered to protect IGBT. This could avoid IGBT to be burned out because of the excessive current. ⊗   No DI.ARST ↑

Read more

AL.070 Encoder does not complete the command issued by servo drive – Delta servo troubleshooting

Archer Delta servo Alarms 2021-04-292021-04-29Alarm handling, Delta Servo 0 Comment

<= See All alarms of Delta servo

Name Description ALM WRN SRV ON Clear
Way

AL.070

Encoder does not complete the command issued by
servo drive

Command is not completed when the barcode is written to the encoder.   ⊗ No after power cycling

Read more

  • ← Previous
  • Next →

Recent Posts

  • Arduino source code for Magnus effect vertical axis wind turbine released
  • Darrieus wind turbine 3D printing files released, you can also build one yourself
  • Magnus Effect Vertical Axis Wind Turbine project files released, you can also build one yourself
  • Wind Power Calculators for various wind turbines-HAWT/VAWT
  • A method of enhancing the Magnus effect by using blades instead of end plates
  • Magnus Effect Vertical Axis Wind Turbine Realistic Demonstration
  • Magnus Effect and Vertical Axis Wind Turbine (VAWT)
  • One picture to understand all pulse sources-A2 servo block diagram
  • Calculation of wind energy and wind turbine efficiency

Categories

標籤搜尋

Alarm handling Delta A2 Delta Servo Electronic gear ratio Fly Saw Following Error Index coordinate Magnus effect Modbus Motion control PLS unit PUU unit Smart Servo STO_Alarm

Archives

Statistics

  • 1,322,625 次瀏覽

HOT POSTS

  • AL.006 Overload - Delta servo troubleshooting
  • AL.011 Encoder Error - Delta servo troubleshooting
  • Troubleshooting summary of Delta A2 servo
  • AL.009 Position Error out of range – Delta servo troubleshooting
  • AL.017 Abnormal EEPROM - Delta servo troubleshooting
  • Wind Power Calculators for various wind turbines-HAWT/VAWT
  • AL.06A The absolute coordinate not initialized - Delta servo troubleshooting

Recent Comments

  • Archer on Troubleshooting summary of Delta A2 servo
  • imam syaefudin on Troubleshooting summary of Delta A2 servo
  • Archer on Magnus Effect and Vertical Axis Wind Turbine (VAWT)
  • Frank on Magnus Effect and Vertical Axis Wind Turbine (VAWT)
  • Srinivasan on AL.013 Emergency stop error – Delta servo troubleshooting
  • Rinku on AL.06A The absolute coordinate not initialized – Delta servo troubleshooting
  • 098ech on High-efficiency but difficult to self-start Darrieus wind turbine experiment – VAWT (2)
  • Archer on Magnus Effect and Vertical Axis Wind Turbine (VAWT)
Copyright © 2025 Smart Servo Home. All rights reserved.
Theme: Accelerate by ThemeGrill. Powered by WordPress.